Press DOWN to SAFETY TIMER -
Adjustable between 20 and 300 minutes. An alarm will sound during charging
after selected time interval during charging has elapsed. Set the time for
about 30% longer than it should take your pack to charge.
Keep in mind that a badly balanced pack may take longer
than normal to charge, so don't set this too tight. A Lipo pack at 1C rate
might take as much as 120 minutes to charge, so timer of about 160180
minutes may be appropriate. Note that while other safety checks based on
capacity and voltage are also working for you, charging should never be
left unattended in any case.
Press DOWN to TCS CAPAClTY - For
LiPo and Lilon battery types Terminal Capacity Selection is available from
50% to 100% of pack capacity. During the charge, the EOS 0610i DUOII
will continually estimate capacity in the pack, and either terminate the
charge or sound a signal tone (and continue charging) when your selected
TCS percentage is reached, depending on the value for you set for TCS END
ACTION. See end of manual for more details on TCS.
Press DOWN to TCS END ACTION -
Values are CONTINUE and STOP. CONTINUE is the default. In this case, when TCS% is reached for settings 50% to 95%, the charger will "beep" 10 times,
but continue charging to 100% until stopped. If TCS ACTION is set to
STOP, the charger will stop charging at that TCS setting and - if
balancing is complete - then give COMPLETE (END) Buzzer according to you
buzzer settings. (or continue till balanced, then give End buzzer).
Press DOWN to DSCH CURRENT - If
you'll be discharging, you'll set the discharge current here. Note that
depending on the voltage of the pack, the current you set may not be
obtainable if the total Volts multiplied by Current (Al exceeds 50w.
Press DOWN to DSCH VOLTAGE per cell
- Lithium types should only be discharged for storage, so we recommend
that you use STORE MODE for that. Otherwise, you need to be sure of the
V/cell setting yourself, according to your battery type. Over-discharge
can damage packs.
Pressing DOWN for a last time
returns you to the 'Memory Select' screen.
At this point, see flowchart (7)
LiIo / LiPo / Al23 BATTERY START. Holding the ENTER key pressed down for
two seconds or more will start the CHARGE, STORE, or DISCHARGE process
(select with UP/DOWN Keys) for LiPo, Lilon, and A123 types, no matter
where in the MEMORY (CHARGE) screens you may be. Additionally- if balancer
circuit is connected - SYNC MODE is available via ENTER (short push) and
UP/DOWN arrow keys.
With "CHARGE START SOLO MODE" selected, hold down
ENTER for 2 seconds. Hold down ENTER again, the charger
will then read **BATTERY CHECK** and then ask you to confirm the number of
cells in your battery pack. Press ENTER (short press) for a final time to
start charging. (if balancer is connected, a 10-second countdown occurs,
then auto start).
Note: If the Lithium-based pack is
NOT connected to the balancer port, the Charger will read NO BALANCER. We
strongly recommend using the balancer at ALL times.
Holding down ENTER (2 seconds) at
any time while charging a battery will then STOP charging (or discharging,
etc ... ).
MODE SELECTIONS
Before Charging/Discharging/Store are in progress,
Pressing the MODE button will scroll you through the MEMORY, DATA VIEW,
BALANCER and USER SETUP screens, allowing you to change
parameters as you like (see charts for each)
During Charging/Discharging/Store ,
Pressing the MODE button will scroll you through the MEMORY, BALANCER and
QUICK VIEW Data screens. (see chart (9) OPERATION and FINISH DISPLAY)
* MEMORY - Short-press UP/DOWN
buttons
you can press ENTER and UP/DOWN to change charge current if
desired. You can also LONG-press (2-seconds) UP button to see each screen
presented in turn at two-second intervals.
* BALANCER - UP/DOWN buttons to see
detailed information on cell balancing, and individual cell voltages
* QUICK VIEW - Shows the following
useful info on a single screen:
CAPACITY mAh/Ah (Charged in "C" or Discharged out "Dn)
INPUT VOLTAGE (Vi)
PACK VOLTAGE (V)
CHARGE CURRENT (A)
CAPACITY (%) of the pack at current time.
---- DATA VIEW
Press the MODE button until you reach the
DATA VIEW screen. (see chart (3) Data View Display)
Use the UP or DOWN key to scroll
through the various information presented:
*INPUT - Current input voltage from
the power supply
*OUTPUT - The output voltage of
charger while charging, or pack voltage of the battery while connected but
not charging
*BAT. RES - The internal resistance
(IR) of the battery pack in mQ.
(IR value appears some seconds after charge is started,
and will become more accurate as charge progresses)
*TEMP and PEAK TEMP - Current Temp,
and Peak Temp recorded during the charge (requires optional temp sensor)
*CHARGE TIME, CHARGE CURRENT
*PEAK CHARGE VOLTAGE
(see chart for other information screens available under Data View)
|